Home > Product

Horizontal rotameter with upper and lower limit alarm switch

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • water horizontal rotameter, water horizontal rotameter ...

    Horizontal rotameter with upper and lower limit alarm switch. US 60.00-65.00 Piece. 2 Pieces (Min. Order) CN Ningbo KIO Flow Instruments Co., Ltd. 14 YRS. 78.0%. 4.9 (7) Contact Supplier. Horizontal rotameter with upper and lower limit alarm switch feature: polysulfone material. alarm switch is optional 360 degree can installed by any angle ...

    Get Price
  • horizontal metal tube rotameter with flow alarm switch ...

    Alibaba.com offers 1,592 horizontal metal tube rotameter with flow alarm switch products. A wide variety of horizontal metal tube rotameter with flow alarm switch options are available to you,

    Get Price
  • JC050 Mechanical Metal Tube Rotameter from China

    JC050 series metal tube rotameter has local indication type and smart remote type with a pointer LCD displaying instantaneous accumulated flow rate, upper-limit, and lower-limit alarm output, accumulative pulse output, batch control, standard two-wire 4-20mA current output, etc. Additionally, this instrument employs advanced microprocessing ...

    Get Price
  • China Rotameter Water, China Rotameter Water

    4.Some models can be equipped with upper or lower limited alarm switch if required. If we have any stock for your order, we will shipped out goods immediately on receipt of your payment. If there’s any quality problems during the warranty period, we ship new spare parts for …

    Get Price
  • Rotameter - Variable Area Flowmeter

    The Variable Area Flowmeter is one of the oldest and mature principles in flow measurement with its simple design: a float rises inside a conically shaped glass tube as the flow increases and its position on a scale can be read off as the flow rate. | Yokogawa Electric Corporation

    Get Price
  • Variable Area Flowmeters - Swagelok

    2021-5-21 · Note: When using one limit switch only, wire to Terminal 1. When using two limits switches, wire the lower switch to Terminal 1 and the upper switch to Terminal 2. Metal-Tube Models M1 Model Lon eohe s t. 1 screw on the connector plug and remove the plug from the junction box. 2. …

    Get Price
  • WALLACE & TIERNAN VAREA-METER FLOW

    Horizontal Measures low volume flows 10% 1/4 in. FNPT 150 psi 200°F 4 in corrosive atmospheres. Stainless-Frame ... temperature limits.) Scales are 2 to 4 inches long and calibrated in gpm and percent for liquids, percent for gases, ... output flow signal and high/low alarm switch. Meter sizes (pipe connections) are 1/2, 1, 1-1/2, and 2 inches ...

    Get Price
  • Accurate rota rotameter For Precise Measurements -

    4.Some models can be equipped with upper or lower limited alarm switch if required. If we have any stock for your order, we will shipped out goods immediately on receipt of your payment. If there’s any quality problems during the warranty period, we ship new spare parts for replacement free for you, or we accept return policy.

    Get Price
  • Basics of Temperature Switch - InstrumentationTools

    2021-8-9 · The span of temperature between upper and lower limits within which the temperature switch can be adjusted to actuate/deactuate. It is expressed for increasing temperature. Set Point. That discrete temperature at which the temperature switch is adjusted to actuate/deactuate on rising or …

    Get Price
  • HG-50 Metal Tube Rotameter - SUYI Group

    2021-8-10 · HG5 series metal tube rotameter has local indication type and smart remote type with a pointer LCD displaying instantaneous accumulated flow rate, upper-limit and lower-limit alarm output, accumulative pulse output, batch control, standard two-wire 4-20mA current output, ect.

    Get Price
  • LZS-15A plastic tube water rotameter with flow alarm

    We want to make sure you are happy with our item. Goods without RMA number will NOT be accepted. We'd like to settle any problem in a friendly manner. Color:as picture shows.

    Get Price
  • LZS-15A plastic tube water rotameter with flow alarm

    6-60,10-100,16-160,25-250 ml/min for gas. LZB-2 0.4-4,0.6-6,1-10,1.6-16 ml/min for liquid. LZQ-3(H=90mm) 0.5-5LPM 1-10LPM. LZM-25 5-35,10-60,10-70,20-110,50-130,10-150 for liquid. LZS-32 0.4-4 0.6-6 1-10T/H.

    Get Price
  • Technical Overview Rotameter Information - Yokogawa

    2020-4-13 · vertical 125 mm with inner thread vertical or horizontal 500 mm vertical Power supply 2/3 wire; 13.5 - 30VDC und 4 wire, 115 VAC, 230 VAC 2 wire ; 13.5 - 30 VDC without Output signal 0-20mA; 4-20mA 4-20mA without Options: Limit switch /K1 to /K10 …

    Get Price
  • Variable Area Flowmeters - Swagelok

    2021-5-21 · Note: When using one limit switch only, wire to Terminal 1. When using two limits switches, wire the lower switch to Terminal 1 and the upper switch to Terminal 2. Metal-Tube Models M1 Model Lon eohe s t. 1 screw on the connector plug and remove the plug from the junction box. 2. …

    Get Price
  • Rotameters (Variable Area Flow Meters)

    Rotameters for Every Application. Variable area (VA) flow meters, or rotameters, are some of the oldest devices used for flow measurement, known for their flexibility across various applications and high reliability. Yokogawa VA flow meters offer simple …

    Get Price
  • Water Rotameter Flow Meter Sensor Indicator Counter

    Online Shopping at a cheapest price for Automotive, Phones & Accessories, Computers & Electronics, Fashion, Beauty & Health, Home & Garden, Toys & Sports, Weddings & Events and more; just about anything else Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return.

    Get Price
  • Industrial Non Contact Liquid Level Sensors

    2020-10-21 · Ultrasonic Level Switch, External Mounted (referred to as “external level switch”) is a new type of level measurement alarm device. Ultrasonic Level Switch is mainly used to detect the liquid level of the storage tank. It can realize the upper and lower limit alarm …

    Get Price
  • Metal tube flowmeter - qf-meter.com

    2019-4-30 · No alarm. Switch alarm output. K1. With a upper switch alarm point. K2. With a floor switch alarm point. K3. With two-switch alarm point . B1. Vertical installation. Structure Note:showflow and header direction in order. B2. Horizontal installation. B3. Side inlet side outlet. B4. Side inlet side outlet. B5. Bottom inlet side outlet . T. Clamp ...

    Get Price
  • www.kytolcom

    2019-10-8 · Kytola struets Oy Olli Kyt l n tie 1 FI-40950 Muurame, Finland Tel. +35 20 779 0690 Fax +35 14 631 419

    Get Price
  • MERCURY SWITCHES FOR BURGLAR ALARM SYSTEMS

    2021-1-31 · (a) Switch current range (dc with resistive load)-both upper and lower limits (b) Switch voltage range (dc)-both upper and lower limits (c) Classification (see Section 2) (d) Tamper resistance features for types 111 and IV (e) Type of material for all components necessary to show compliance with para- graph 4.2.2

    Get Price
  • HIGHLANDER Commercial Platform Lift

    2021-5-27 · Setting the Limit Switches Your lift is equipped with upper and lower limit switches. The vertical location of these switches may be adjusted to fit your application. Typically the upper limit switch will need to be adjusted so the platform will stop level with the upper landing. The lower limit will typically not need adjusting. Step 1

    Get Price
  • ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO.,

    2018-11-7 · Upper and lower temperature limit alarm function (built inside temperature controller) Ovenheat protector Cartridge fuse Specimen power supply control terminal Model PVC-212 PVC-232 PVC-332 PVHC-212 PVHC-232 PVHC-332 PVHC-232MS PVHC-332MS System Back-to-front horizontal laminar circulation system

    Get Price
  • General FA-M3 Specification F3CU04-0S, F3CU04-1S ...

    2020-4-10 · limit, deviation upper limit, deviation lower limit, deviation upper/lower limit, and within deviation upper/lower limit, all with or without waiting Number of alarm outputs (input relays) 4 alarm outputs per loop (2 input relays for alarms 1 and 2 for each loop) Alarm ON-delay function Yes Warm-up time 30 minutes min. Max. allowable ambient ...

    Get Price
  • General DX100, DX200 Specification /S120 Enhancement

    2020-4-10 · Alarm types displayed with alarm marks; Upper-limit alarm (H) Lower-limit alarm (L) Delay upper-limit alarm (T) Delay lower-limit alarm (t) Display rate switching functions General functions: Two speed time/div is available to switch by key operations and remote input. Secondary setting time/div speed is effective only on real-time monitor screen.

    Get Price
  • Cable & Antenna Analyzer with Optional VNA and VVM

    2020-9-8 · Limit Active Limit (Upper/Lower), Limit State (O ff, Single, Segmented), Move Active Limit, Edit Segments (42 upper and 42 lower segments maximum), Limit Alarm (On/Off), Pass/Fail (On/Off), Limit Preset ... Vertical Range Return Loss 0 dB to 1000 dB Vertical Range …

    Get Price
  • VA Master FAM540 Metal Cone Variable Area Flowmeter

    2021-2-15 · Power supply Without alarm signalling unit: no power supply Analog indicator with alarm signaling unit: 8 V DC via switch amplifier Analog indicator with transmitter: 10 to 46 V DC (Ex: 10 to 30 V DC) Indicator housing mater ial Al Si 12 material number 3.2582 …

    Get Price
  • DKG-109 AUTOMATIC MAINS FAILURE UNIT

    2018-6-7 · The mains voltages upper and lower limits are programmable. 3 MAINS-L2 4 MAINS-L3 5 MAINS NEUTRAL Input, 0-300V-AC Neutral terminal for the mains phases. 6 LOW OIL PRESSURE Digital inputs These inputs have programmable characteristics selected via the program menu. Each input may be driven by a

    Get Price
  • Siemens 6ES7136-6BA00-0CA0

    2018-6-27 · permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Yes Input current Current consumption (rated value) 75 mA; without load Current consumption, max. 21 mA; From the backplane bus Encoder supply Number of outputs 8 6ES7136-6BA00-0CA0 Subject to change without notice Siemens 6ES7136 ...

    Get Price
  • Product Categories

    Dwyer offers different types of Dial Flowmeters for various applications. Flow meters measure water, oil, gas or air flow rates. Applications include calculating required fill or drain times for tanks, water towers, backflow prvention, heat exchangers, and oil & gas equipment. In-line flowmeters …

    Get Price
  • ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO.,

    2018-11-7 · Upper and lower temperature limit alarm function (built inside temperature controller) Ovenheat protector Cartridge fuse Specimen power supply control terminal Model PVC-212 PVC-232 PVC-332 PVHC-212 PVHC-232 PVHC-332 PVHC-232MS PVHC-332MS System Back-to-front horizontal laminar circulation system

    Get Price
  • Temperature Chamber Series

    2018-4-26 · Temperature Chamber Series CAT.NO.E94190-O1804 TS4B30C02 (The contents of this catalog is as of April, 2018.) Specifications are subject to change without notice due to design improvements. Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks. ESPEC CORP. (Overseas subsidiaries not included)

    Get Price
  • User´s ROTAMETER RAMC Manual Variable Area

    2021-6-24 · Set upper range limit (set to scale upper range as specified when ordered) Parameter: OUT_SCALE Sub-parameter: EU_at_0% Set lower range limit (set to scale lower range as specified when ordered) Parameter: CHANNEL 0x01 Volume Flow 0x02 Mass Flow 4. Start of Operation

    Get Price
  • Brooks GT1600

    2020-4-29 · Alarms Ring initiatorhigh low alarm Hazardousarea approvals Material Certificationto DIN 3.1 Declarationof Compliance 2.1 Oxygen Service Reedswitch high low alarm VerticalIN/OUT Horizontal IN VerticalOUT Horizontal IN VerticalOUT 316/316L(dualcertifiedstainless steel) Viton®, Buna N, …

    Get Price
  • UNIVERSAL GAS VALVES C6058A - Libero.it

    2002-7-16 · switch to ON/OFF control of the external electrical circuit. These switches are widely used to detect the upper limit or lower limit pressure of gas or air to be supplied to a gas burner, or to detect the clogging of the interlock filter of a burner blower. SPECIFICATIONS Product range There are two versions available: stand alone and flange

    Get Price
  • Level Switches - Float Switches - Power Control Products ...

    The D50 level switch is ideal for water tank level control. The switch is positioned at the top of the tank with two adjustable floats down in the water. Suitable for water tank fill or empty. 20amp single pole double throw microswitch. Fully adjustable upper and lower levels.

    Get Price
  • Typical Electrical Drawing Symbols and Conventions.

    2019-1-11 · 63 - Pressure Switch 64 - Ground Detector Relay 65 - Governor 66 – Notching or jogging device 67 - AC Directional Overcurrent Relay 68 - Blocking or “out of step” Relay 69 - Permissive Control Device 71 - Level Switch 72 - DC Circuit Breaker 74 - Alarm Relay 75 - Position Changing Mechanism 76 - DC Overcurrent Relay

    Get Price
  • 180 Degree Panoramic Outdoor PIR Detector : WX

    2021-8-2 · Solid State switch, 10 VDC 0.01 A max. [N.O. or N.C.] is selectable: Tamper output: N.C. 28 VDC 0.1 A max. Open when either the cover, main or base unit is removed: Tamper output is shared with trouble output. LED indicator (DIP switch ON or Walk test) Red LED : 1. Warm-up 2. Alarm: Red LED : 1. Warm-up 2. Alarm …

    Get Price
  • UNDERSTANDING COLORS AND GAMUT

    2021-3-16 · lower gamut limit has been exceeded for the red and blue channel. In the case of composite and luma gamut errors upper case “L” and “C” indicate the Luma or Chroma limit have been exceeded and lower case letters “l” and “c” indicate the lower limit have been exceeded. The user can use this information to make adjustment of the

    Get Price
  • water horizontal rotameter, water horizontal rotameter ...

    Horizontal rotameter with upper and lower limit alarm switch. US 60.00-65.00 Piece. 2 Pieces (Min. Order) CN Ningbo KIO Flow Instruments Co., Ltd. 14 YRS. 78.0%. 4.9 (7) Contact Supplier. Horizontal rotameter with upper and lower limit alarm switch feature: polysulfone material. alarm switch is optional 360 degree can installed by any angle ...

    Get Price
  • horizontal metal tube rotameter with flow alarm switch ...

    Alibaba.com offers 1,592 horizontal metal tube rotameter with flow alarm switch products. A wide variety of horizontal metal tube rotameter with flow alarm switch options are available to you,

    Get Price
  • Accurate flowtech rotameter For Precise Measurements ...

    Variable area flowmeter with alarm limit switch rotameter FLOWTECH pc;as 5% glue/elbow. 10.00-200.00 Piece. 1 Piece ... Horizontal rotameter with upper and lower limit alarm switch. 60.00-65.00 Piece. 2 Pieces ... 14 YRS. 5.0 (4) Contact Supplier. Horizontal rotameter with upper and lower limit alarm switch feature: polysulfone material ...

    Get Price
  • JC050 Mechanical Metal Tube Rotameter from China

    JC050 series metal tube rotameter has local indication type and smart remote type with a pointer LCD displaying instantaneous accumulated flow rate, upper-limit, and lower-limit alarm output, accumulative pulse output, batch control, standard two-wire 4-20mA current output, etc. Additionally, this instrument employs advanced microprocessing ...

    Get Price
  • China Rotameter Water, China Rotameter Water

    4.Some models can be equipped with upper or lower limited alarm switch if required. If we have any stock for your order, we will shipped out goods immediately on receipt of your payment. If there’s any quality problems during the warranty period, we ship new spare parts for …

    Get Price
  • Rotameter - Variable Area Flowmeter

    The Variable Area Flowmeter is one of the oldest and mature principles in flow measurement with its simple design: a float rises inside a conically shaped glass tube as the flow increases and its position on a scale can be read off as the flow rate. | Yokogawa Electric Corporation

    Get Price
  • Variable Area Flowmeters - Swagelok

    2021-5-21 · Note: When using one limit switch only, wire to Terminal 1. When using two limits switches, wire the lower switch to Terminal 1 and the upper switch to Terminal 2. Metal-Tube Models M1 Model Lon eohe s t. 1 screw on the connector plug and remove the plug from the junction box. 2. …

    Get Price
  • WALLACE & TIERNAN VAREA-METER FLOW

    Horizontal Measures low volume flows 10% 1/4 in. FNPT 150 psi 200°F 4 in corrosive atmospheres. Stainless-Frame ... temperature limits.) Scales are 2 to 4 inches long and calibrated in gpm and percent for liquids, percent for gases, ... output flow signal and high/low alarm switch. Meter sizes (pipe connections) are 1/2, 1, 1-1/2, and 2 inches ...

    Get Price
  • Accurate rota rotameter For Precise Measurements -

    4.Some models can be equipped with upper or lower limited alarm switch if required. If we have any stock for your order, we will shipped out goods immediately on receipt of your payment. If there’s any quality problems during the warranty period, we ship new spare parts for replacement free for you, or we accept return policy.

    Get Price
  • Basics of Temperature Switch - InstrumentationTools

    2021-8-9 · The span of temperature between upper and lower limits within which the temperature switch can be adjusted to actuate/deactuate. It is expressed for increasing temperature. Set Point. That discrete temperature at which the temperature switch is adjusted to actuate/deactuate on rising or …

    Get Price
  • FLOwMETERS - ROTAMETER

    2017-7-9 · in its lower part and wider in the upper); they are installed in a perfectly vertical position along with the pipe of which we want to know the flow. Within the tube there is a stainless steel floater, that will move upwards reaching a specific height depending on the weight of the floater and water pressure.

    Get Price
  • General FA-M3 Specification F3CU04-0S, F3CU04-1S ...

    2020-4-10 · limit, deviation upper limit, deviation lower limit, deviation upper/lower limit, and within deviation upper/lower limit, all with or without waiting Number of alarm outputs (input relays) 4 alarm outputs per loop (2 input relays for alarms 1 and 2 for each loop) Alarm ON-delay function Yes Warm-up time 30 minutes min. Max. allowable ambient ...

    Get Price
  • Bruno VPL -3300B Series

    2016-3-16 · Upper/lower limit switches Travel carriage Batteries. ... and emergency stop with audio visual alarm Lower Landing Pit Lift Height 3” Pit Depth Upper Landing ... The sensor can be mounted anywhere below the lower limit switches. When water is detected, the platform will stop moving

    Get Price
  • Liquid Displacer Level Switches - MAGNETROL

    Liquid Displacer Level Switches Magnetrol's displacement type level switches offer the industrial user a wide choice of alarm and control configurations. Each unit utilizes a simple buoyancy principle and is well suited for simple or complex applications, such as foaming or surging liquids or agitated fluids, and usually costs less than other types of level switches.

    Get Price
  • How to Wire a Limit Switch

    A limit switch is used to control electrical devices by breaking and completing electrical circuits. It has three terminals. The power input terminal is called the common terminal and is used to connect the switch to a power source. It is abbreviated 'COM.' The other terminals are the normally open ('NO'

    Get Price
  • Air Flowmeter MCF Series - Azbil North America

    2016-3-8 · Selectable from integrated pulse output,*2 instantaneous flow rate switch upper/lower limit, integrated flow switch count up/down, and alarm output PA5 series VA connector with 4 pins 5-digit 7-segment LED/display switchable among instantaneous flow rate, integrated flow rate, and cost, displayed for 5 seconds after the switch is pressed

    Get Price
  • McDonnell & Miller

    2009-11-25 · • This low water cut-off must be installed in series with all other limit and operating controls installed on the boiler. After installation, check for proper operation of all of the limit and ... with a horizontal upper and lower (G) equalizing piping at the ... terminals 3 and 4 are for the low level alarm circuit contacts. Blue switch ...

    Get Price
  • Configure Alarm table - Beckhoff Automation

    2017-12-21 · Change alarm group: Press this button to get the selection tree of the alarm configuration, which offers all alarm groups currently defined. Choose the desired group (which even may contain just one alarm). Priority: Define the priority for which you …

    Get Price
  • Instruction manual for digital light beam display ...

    2017-11-11 · S13. Fourth alarm mode SL3.=0 No alarm SL3.=1 Fourth alarm for lower limit alarm SL3.=2 ourth alarm is upper limit alarm S14. Cold patching method and light beam display mode SL4=0 Internal cold end compensation, light column display as line display SL4=1 External cold end compensation, light column display as line display

    Get Price
  • Model UT150L Limit Controller - Yokogawa

    2020-4-11 · To move the bracket, push down the center of the upper and lower parts of the controller softly. The bracket is released from the latch. 4. Panel Cutout Dimensions and External Dimensions 1. General Mounting 2. Side-by-side Close Mounting (Splash-proof construction is unavailable) Unit: mm max. 61 Panel thickness max. 44.8 max. 47.8 max. 44.8 ...

    Get Price
  • Bruno VPL -3300B Series

    2016-3-16 · Upper/lower limit switches Travel carriage Batteries. ... and emergency stop with audio visual alarm Lower Landing Pit Lift Height 3” Pit Depth Upper Landing ... The sensor can be mounted anywhere below the lower limit switches. When water is detected, the platform will stop moving

    Get Price
  • PY600AC Sliding Gate Opener User Manual

    2017-9-3 · Limit switch Spring limit switch Magnetic limit switch Noise ≤58dB Working duty S2, 15min Recording of up remote controls 25 Frequency 433.92 MHz Working temperature -20°C ~ +70°C Package weight 9.4Kg 4. Installation PY600AC sliding gate opener is applicable to gate weight less than 600kg, and length of the sliding

    Get Price
  • Amazon.com: NOYITO Voltage Relay Module Upper Lower Limit ...

    Buy NOYITO Voltage Relay Module Upper Lower Limit Detection Control Switch Off ON Over Voltage Protection Battery Charge Discharge Timing (12V): Serial Adapters - Amazon.com FREE DELIVERY possible on eligible purchases

    Get Price
  • SS/364XS 1 2600T Series Pressure Transmitters

    2018-5-10 · Output current limits (to NAMUR standard) Overload condition - Lower limit: 3.8mA (configurable from 3.7 to 4mA) - Upper limit: 20.5mA (configurable from 20 to 22.5mA) Alarm current Minimum alarm current: 3.7mA (configurable from 3.7 to 4mA) Maximum alarm current: 22mA (configurable from 20 to 22.5mA) Standard setting: maximum alarm current R ...

    Get Price
  • INSTRUCTION MANUAL

    2021-6-17 · • This low water cut-off must be installed in series with all other limit and operating controls installed on the boiler. After installation, check for proper operation of all of the limit and ... , do not exceed the switch contact rating. ... with a horizontal upper and lower (G) equalizing piping at the

    Get Price
  • Set Up Manual - Omega Engineering

    2019-1-29 · while maintaining a liquid level range of 90 to 65 inches. High and low alarm output circuits will be activated at 105 and 55 inches. Transducer Range 138.0 inches H2O Transducer Height 11.0 Upper Limit of Window 110.0 Lower Limit of Window 50.0 High Alarm/Fault Level 105.0 Sump ON Level 90.0 Sump OFF Level 65.0 Low Alarm/Fault Level 55.0

    Get Price
  • Product Bulletin 61-12 A - Parker Hannifin

    2017-6-16 · The switch is mounted below the low level alarm level switch and is used to turns off the liquid pump in order to prevent cavitaion . Wired in the N .C . position . • Level Control This switch maintains a desired refrigerant level in the vessel by turning on and off a liquid feed solenoid valve . Wired in the N .O . position . • High Level ...

    Get Price
  • INSTRUCTION MANUAL MM-200J

    2016-9-30 · gle throw switches to control the water feeder and the low water cut-off.The low water cut-off switch is between terminals marked “1” and “2”. A second switch is located between terminals marked “3” and “4”. This can be used to operate a low water alarm or a McDonnell & Miller electric water feeder.

    Get Price
  • Digital Storage Oscilloscope

    2016-12-16 · oscilloscope supports horizontal and vertical zoom, X-Y display mode, and signal analytics, including cursors, measurements, and a Fourier Transform to show a …

    Get Price
  • How to Wire a Limit Switch

    A limit switch is used to control electrical devices by breaking and completing electrical circuits. It has three terminals. The power input terminal is called the common terminal and is used to connect the switch to a power source. It is abbreviated 'COM.' The other terminals are the normally open ('NO'

    Get Price
  • DK37 M8

    The DK37 M8 is a variable area (VA) flowmeter with electrical signal output and bargraph indication or mechanical indicator with two optional limit switches. The versatile all-metal measuring device is suitable for flow measurement of gases and liquids. Due to its sturdy design, the VA meter can be used at temperatures up to +200°C +392°F ...

    Get Price
  • Air Flowmeter MCF Series - Azbil North America

    2016-3-8 · Selectable from integrated pulse output,*2 instantaneous flow rate switch upper/lower limit, integrated flow switch count up/down, and alarm output PA5 series VA connector with 4 pins 5-digit 7-segment LED/display switchable among instantaneous flow rate, integrated flow rate, and cost, displayed for 5 seconds after the switch is pressed

    Get Price
  • Bruno VPL -3300B Series

    2016-3-16 · Upper/lower limit switches Travel carriage Batteries. ... and emergency stop with audio visual alarm Lower Landing Pit Lift Height 3” Pit Depth Upper Landing ... The sensor can be mounted anywhere below the lower limit switches. When water is detected, the platform will stop moving

    Get Price
  • KROHNE H250-C Variable Area Flow Meter

    KROHNE H250-C variable area flow meters are available in sizes from 1/2' to 4' with corresponding flow rates ranging from as low as 0.66 gph (0.011 scfm for gases) to as high 15,850 gph (217 scfm). The basic accuracy for flow readings is ±2.5%. Due to its …

    Get Price
  • Bruno VPL -3300B Series

    2016-1-5 · Vertical platform lifts (VPLs) are a cost-effective solution to make a church, school, office or other public building accessible for ... Upper/lower limit switches Travel carriage Batteries. Bruno VPL-3300B Series nclosure Design and Planning Guide ... and emergency stop with audio visual alarm Lower Landing Pit Lift Height 3” Pit Depth ...

    Get Price
  • Set Up Manual - Omega Engineering

    2019-1-29 · while maintaining a liquid level range of 90 to 65 inches. High and low alarm output circuits will be activated at 105 and 55 inches. Transducer Range 138.0 inches H2O Transducer Height 11.0 Upper Limit of Window 110.0 Lower Limit of Window 50.0 High Alarm/Fault Level 105.0 Make-up OFF Level 90.0 Make-up ON Level 65.0 Low Alarm/Fault Level 55.0

    Get Price
  • Product data sheet 6ES7214-1AD23-0XB0

    2014-2-4 · lower limit 1 upper limit 256 Counting range lower limit 0 upper limit 32767 S7 times Number 256 of which retentive with battery adjustable Yes ; via high-performance capacitor or battery upper limit 64 Time range lower limit 1€ms upper limit 54€min ; 4 timers: 1 ms to 30 s; 16 timers: 10 ms to 5 min; 236 timers: 100 ms to 54 min

    Get Price
  • Float level switches

    2021-8-21 · All float operated liquid level controls operate on the basic buoyancy principle which states 'the buoyancy force action on an object is equal to the mass of liquid displaced by the object.' As a result, floats ride on the liquid surface partially …

    Get Price
  • UNIVERSAL GAS VALVES C6058A - Libero.it

    2002-7-16 · switch to ON/OFF control of the external electrical circuit. These switches are widely used to detect the upper limit or lower limit pressure of gas or air to be supplied to a gas burner, or to detect the clogging of the interlock filter of a burner blower. SPECIFICATIONS Product range There are two versions available: stand alone and flange

    Get Price
  • Thermo Scientific -20C Laboratory and Enzyme Freezers

    2019-4-22 · 6. Door ajar — illuminated when the freezer door is open and the alarm is activated, and the key switch is turned to the alarm position). 7. Battery low — illuminated when the backup battery is low. 8. Decrease — pushbutton used to decrease setpoint values …

    Get Price